Search

SCADA Articles on SCADA World

SCADA virtualisation with WinCC Version 7

2011-12-21 12:01:11views: 1336ControlEngeneering

SCADA virtualisation with WinCC Version 7

As automation solutions become increasingly complex, it follows that the effort required to maintain both hardware and software will also increase. PCs must be provided with suitable specification and operating systems to support the applications. Whilein operation, these systems must be constantly reviewed and updated normally through the application of security patches, updates and service packs. This will apply to every installed system and application program during the lifetime of the system.

To reduce the amount of ongoing administration and maintenance effort associated with update issues, the automation world is turning increasingly to virtualisation and the opportunity it provides to decouple applications from hardware. This creates the ability to centrally manage the application and simplify back up and restoration of the system environment. Client environments can be installed just once and distributed among one or two virtualisation servers using virtual sessions (instances). It is also easier to implement IT security solutions on central virtualisation servers than via numerous client stations. Virtualisation also eliminates the restriction of target devices to a particular hardware, allowing more complex applications to run on simple, low-cost, and robust thin clients.

Virtualisation

A service pack for Siemens Simatic WinCC Version 7 SCADA system promises owners of automation solutions, the means to reduce hardware, administration, and maintenance costs. One of the innovations of the system is the virtualisation option for both WinCC clients and WinCC servers on various hardware platforms. Through this option, owners of medium and large automation solutions, as well as smaller multiple station and single station systems can reduce hardware, administration, and maintenance costs. The virtualisation is based on VMware ESX(i) 4.1 - one of VMware's globally-established hypervisor applications for virtualisation. It is installed on central (and ideally redundant) virtualisation servers with adequate performance in order to ensure appropriate background allocation of available system resources (CPUs, work memory, storage media, communication, etc.) among the virtual client and server applications. This type of virtual server can accommodate up to 25 virtual client sessions of different types without these sessions affecting each other – all on a single hardware platform. Access to these virtual client sessions is via Ethernet using a standard Remote Desktop Protocol (RDP) session. This means that there is no longer a need for powerful client side hardware, which opens the door for the use of simple, compact, and low-cost thin clients, such as robust PDAs or panels without rotating parts, e.g., with Solid State Disk (SSD), for operator control and monitoring in the field. As a result, it is much easier to choose a client and to use clients in harsh industrial environments, including hazardous areas. If a failure occurs, it is possible to use a thin client with higher or lower screen resolution without making any additional settings, which minimises downtimes.

Consolidation reduces costs

The ability to operate several WinCC servers and/or client sessions on a central platform (also away from the field level) reduces PC hardware and network components, as well as acquisition costs and ongoing operating costs for power/maintenance/spare part considerations. The number of client sessions is limited only by the performance capability of the virtualisation server and not by the SCADA system. One advantage of virtualisation is that the operating system and automation application no longer has to be individually installed and maintained on every client. Virtualisation reduces this to a one-time installation or a central updating of the VMware and of a small number of different client sessions on the server. The latter can be easily replicated so that the benefits increase with the number of clients. Backups and systems restores are made centrally and in a short time. In addition, it is possible to migrate existing, completely configured systems to a new hardware platform without a time-consuming installation process.

Protection from malicious software

Every inadequately protected operator control station having a USB port, floppy disk drive, or hard disk drive is potentially vulnerable to a certain degree to malicious software and requires more effort in this regard than a virtual system solution. This is because the lack of interfaces in simple thin clients makes them generally less vulnerable to malware than "fully-fledged" PCs. Providing security at a central location requires less effort, quite apart from the fact that the operating systems of professional server solutions, which frequently are not Windows-based, are generally at a lower risk. Certain hardware and software errors can cause the PC system itself to fail, thus rendering operator control clients inoperable. This calls for a replacement, which is not always possible without interrupting the active process. In virtualised solutions, it is possible to achieve high levels of availability – even when system components require replacement – through the use of RAID systems. Software can be updated during operation, clients can be added to or removed from the system, and the switchover from one client to the other can take place within a few seconds. In addition, a configurable alarm management function is available which notifies the operator in the event of system errors or when critical system loads are reached. All of this contributes to high availability and productivity.

Link: http://www.controlengeurope.com/

SCADA Articles

Using Free Tools To Detect Attacks On SCADA Networks
2015-05-09 14:28:25views: 1822

ICS/SCADA experts say open-source network security monitoring software is a simple and cheap way to catch hackers targeting plant operations. Operators at Natanz nuclear facility in Iran might well have caught Stuxnet before it spread and sabotaged operations at the plant if they had been watching the wires for anomalous network traffic, a pair of ICS/SCADA experts say.

Hackers gain full control of critical SCADA systems
2015-05-09 14:04:07views: 1914

Russian researchers have found vulnerabilities in industrial control systems that they say grant full control of systems running energy, chemical and transportation systems. The vulnerabilities were discovered by researchers who over the last year probed popular and high-end ICS and SCADA systems used to control everything from home solar panel installations to critical national infrastructure.

SCADA Attacks Double in 2014
2015-05-06 07:17:15views: 1688

Annual threat report from Dell Security shows not only a significant surge in the number of attacks on retail credit card systems, but industrial SCADA systems as well, which are much more likely to go unreported.
For Dell to report an annual surge in point-of-sale (POS) attacks aimed at payment card infrastructures might not be such a surprise to people who pay any attention to the news.

The Industrial Software Revolution Begins Now
2013-10-16 11:33:59views: 2270

Invensys is kicking off the conference “The Industrial Software Revolution Begins Now” and underscoring the ‘revolution’ concept with the release of its Wonderware InTouch 2014 and Wonderware System Platform 2014 software.

Integrating Video into HMI/SCADA
2012-06-29 10:19:55views: 2559

The useful integration of video with industrial control systems has been a reality for a few years, but a burst of applications and installations is on the horizon. Cheaper bandwidth, wide availability of Internet protocol (IP) cameras, and greater familiarity with industrial Ethernet networks seem to be driving user interest.

AdvancedHMI - a different approach to HMI development
2012-06-14 10:46:48views: 1832

AdvancedHMI base package is a free software used to build HMIs that display information residing in a PLC. You will find it to be one of the fastest platforms to build an HMI with. The software takes advantage of the Visual Basic .NET development environment so effort is focused on the core software and not reinventing a development environment.

Web Services and SCADA
2012-06-12 23:06:33views: 1402

Web services can be another method for connectivity to SCADA and MES systems. They can retrieve tomorrow's weather, the price of stocks or commodities, the time of sunrise and sunset, and a slew of other publicly-available resources.

SCADA virtualisation with WinCC Version 7
2011-12-21 12:01:11views: 1337

As automation solutions become increasingly complex, it follows that the effort required to maintain both hardware and software will also increase. PCs must be provided with suitable specification and operating systems to support the applications.

Cloud-Based SCADA Systems: The Benefits and Risks
2011-12-20 22:57:31views: 957

Cloud computing is a hot topic. As people become increasingly reliant on accessing important information through the Internet, the idea of storing or displaying vital real-time data in the cloud has become more commonplace. With tech giants like Apple, Microsoft, and Google pushing forward the cloud computing concept, it seems to be more than just a passing trend.

An alternative to DCS or PLC/SCADA
2011-10-04 13:46:22views: 900

Traditionally, users have had a choice between a DCS or a PLC/SCADA approach when selecting a control system for use in process control applications. A key benefit of traditional DCSs was that the suppliers took a ‘systems approach’ and it was designed for large scale applications.